SRICITY PRIDE

NO. OF ACERS
15
Services Provided

Sewer supply network

Products Used

Supreme Pipes 
Ultra Manhole

employees work area
working site employee checking the land
land with working for pipe line construction
construction place
pipe line equpment
cement stones for pipe line construction
working site
working plan checking site

Project Background

Leenus India was contracted by Sri City Private Limited to execute sewer system installation over a 15-acre site at Sricity Pride. The project included 1,618 meters of the sewer line, which needed to be completed in a short time-frame whilst also complying with the set quality standards.

Challenges

The main hurdle was the black cotton soil which caused most of the space underneath the pipes to be refilled with finer material. It involved repeated water application and soil compaction hence increasing the time taken for the project and making the whole process of installation complicated.

Solutions and Approach

The above challenges had to be faced back on the system, which includes how Leenus India went on working through a planned and systematic approach:
  • Proper Planning: Our team made a proper assessment of site and accordingly planned pipeline routes in such a manner such that it would reduce the quantum of excavation coupled with a comprehensive plan. Our proactive approach assured that no hurdles come in executing the job and all jobs were completed within the scheduled timeframe.
  • Quality Materials: For the sewer system, we made use of high-quality Supreme pipes made of PVC and HDPE, sourced from Supreme Industries. Such pipelines were used for the reason that they are at high resistance to all kinds of corrosion, as well as other local factors that they might be exposed to.
  • Advanced Techniques: This involved the use of advanced trenchless technology through horizontal drilling to reduce disruption on the surface and speed up the installation process. Such was particularly the case for those instances where the meetings passed through strict terrain that did not compromise the integrity of the surrounding structure in any way.

Execution

  • Site preparation: The site was leveled and cleared in order to lay the base for a stable pipeline installation. Safety measurements were taken in order to protect not only the laborers on site but also the community Individuals within the environs.
  • Material delivery:Best quality PVC pipes and HDPE pipes manufactured by Supreme Industries were supplied well in time at the site, thereby ensuring work continuity without any inhibition and its completion according to schedule .
  • Installation: Our competent technicians fitted the pipes properly, ensuring that, at all joints, there was perfect line alignment, jointing, and sealing to avoid leakages and to optimize flow. The quality of installations was checked at regular intervals.
  • Testing and Commissioning: After the installation, intensive testing operation was carried out on the sewer system to prove it for its working and conformation to the local authority’s regulations. The system was commissioned with final adjustments in order to ensure it works as it should.
Solutions and Approach

Detailed Planning: 
Leenus India in the  Construction Engineering   Department has developed a specially tailored project strategy with respect to the peculiar soils. Also, the installation activity was conducted in gradual and reasonable steps so that complete soil preparation and effective laying out of the pipeline was done, allowing enough time for compaction.
Premium Materials:
We procured the best sewer pipes to use in very complicated soil conditions. There were also tests of the established standards. All materials passed the required quality check. This assured the Sewer system durability.
Efficient Workforce Management:
A competent workforce was structured such as to work in shifts hence continuous progress on the site. Senior engineers supervised the work so that any issues or Problems that came up were resolved immediately so that the work did not slow down because of the soil problems encountered.
Advanced Techniques:
Machines were utilized for the soil compaction and the method was combined with a constant watering procedure to ensure enough water was available. Such method prevented any deformation and movement of the portion of the pipeline that had already been laid.

Execution

Site Preparation:
Indeed, before the commencement of works on  site, we ascertained this, and as a result, we carried out soil studies to determine what even more needs to be refilled and compacted.
Material Delivery :
Timber materials were supplied using a just-in-time delivery system. They were delivered based on reaching the appointed stage in the installation process. Thus, the processes were not delayed.
Installation:
The sewer pipeline installation was done in stages bearing in mind the site conditions especially the soils and even the compaction requirements. Such a sequential approach made it possible for all the work to be done in a short period of time and without compromising on quality.
Testing and Commissioning:
In addition to routine checks, such as visual inspections, the quality of the sewer system was evaluated and problems were rectified as well, where necessary. Fine-tuning was carried out and all aspects accounted for to achieve the best system before handing it over to the client.

Timely Completion
Though it was unable to avoid the challenges, Leenus India managed to meet timelines and finished the sewer installation on schedule..
Enhanced Efficiency
Improvement in the efficiency of execution was also observed due to effective strategy implemented to the ordering of soil and skylight installation processes.
Client Satisfaction
Sri City Private Limited expressed a high degree of satisfaction regarding the quality of work and handling of challenges during the course of the project.

Conclusion

Leenus India’s collaboration with Sri City Private Limited on the Sricity 2 project illustrates their expertise in managing complex infrastructure projects. Their effective planning and execution not only addressed the challenges of black cotton soil but also resulted in a reliable sewer system, fulfilling the project’s requirements and ensuring client satisfaction.
Get a quick enquiry